Yazar "Yalcin, Huseyin Cagatay" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Finite Element Analysis of Evolut Transcatheter Heart Valves: Effects of Aortic Geometries and Valve Sizes on Post-TAVI Wall Stresses and Deformations(Mdpi, 2025) Mutlu, Onur; Mazhar, Noaman; Saribay, Murat; Yavuz, Mehmet Metin; Ozturk, Deniz; Ghareeb, Abdel Naser; Yalcin, Huseyin CagatayBackground/Objectives: For transcatheter aortic valve implantation (TAVI) therapy, a catheter-guided crimped valve is deployed into the aortic root. Valve types such as Edwards balloon-expandable valves and Medtronic self-expandable valves come in different sizes and are chosen based on patient-specific aortic anatomy, including aortic root diameter measurement. Complications may arise due to variations in anatomical characteristics and the implantation procedure, making pre-implantation assessment important for predicting complications. Methods: Computational modeling, particularly finite element analysis (FEA), has become popular for assessing wall stresses and deformations in TAVI. In this study, a finite element model including the aorta, native leaflets, and TAVI device was used to simulate procedures and assess patient-specific wall stresses and deformations. Results: Using the Medtronic Evolut R valve, we simulated TAVI for 14 patients to analyze the effects of geometrical variations on structural stresses. Virtual TAVIs with different valve sizes were also simulated to study the influence of TAV size on stresses. Our results show that variations in aortic wall geometries and TAV sizes significantly influence wall stresses and deformations. Conclusions: Our study is one of the first comprehensive FEA investigations of aortic geometrical variations and valve sizes on post-TAVI stresses, demonstrating the non-linear relationship between aortic dimensions, TAV sizes, and wall stresses.Öğe Material modeling and recent findings in transcatheter aortic valve implantation simulations(Elsevier Ireland Ltd, 2024) Mutlu, Onur; Saribay, Murat; Yavuz, Mehmet Metin; Salman, Huseyin Enes; Al-Nabti, A. Rahman D. M. H.; Yalcin, Huseyin CagatayBackground and objective: Transcatheter aortic valve implantation (TAVI) has significantly transformed the management of aortic valve (AV) diseases, presenting a minimally invasive option compared to traditional surgical valve replacement. Computational simulations of TAVI become more popular and offer a detailed investigation by employing patient-specific models. On the other hand, employing accurate material modeling procedures and applying basic modeling steps are crucial to determining reliable numerical results. Therefore, this review aims to outline the basic modeling approaches for TAVI, focusing on material modeling and geometry extraction, as well as summarizing the important findings from recent computational studies to guide future research in the field. Methods: This paper explains the basic steps and important points in setting up and running TAVI simulations. The material properties of the leaflets, valves, stents, and tissues utilized in TAVI simulations are provided, along with a comprehensive explanation of the geometric extraction methods employed. The differences between the finite element analysis, computational fluid dynamics, and fluid-structure interaction approaches are pointed out and the important aspects of TAVI modeling are described by elucidating the recent computational studies. Results: The results of the recent findings on TAVI simulations are summarized to demonstrate its powerful potential. It is observed that the material properties of aortic tissues and components of implanted valves should be modeled realistically to determine accurate results. For patient-specific AV geometries, incorporating calcific deposits on the leaflets is essential for ensuring the accuracy of computational findings. The results of numerical TAVI simulations indicate the significance of the selection of optimal valves and precise deployment within the appropriate anatomical position. These factors collectively contribute to the effective functionality of the implanted valve. Conclusions: Recent studies in the literature have revealed the critical importance of patient-specific modeling, the selection of accurate material models, and bio-prosthetic valve diameters. Additionally, these studies emphasize the necessity of precise positioning of bio-prosthetic valves to achieve optimal performance in TAVI, characterized by an increased effective orifice area and minimal paravalvular leakage.











