Comparison of Anisotropic Analytical Algorithm and Acuros XB Calculation Algorithms on Intensity-modulated Radiotherapy and Volumetric Modulated Arc Therapy Techniques for Nasal Cavity and Paranasal Sinus Tumors: Effects on Integral Radiation Dose

Yükleniyor...
Küçük Resim

Tarih

2019

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

KARE PUBL

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

OBJECTIVE This study aims to investigate the dosimetric effects of Acuros XB (AXB) and Anisotropic Analytical algorithms (AAA) on intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques for nasal cavity and paranasal sinus tumors. METHODS This study included 10 patients with the nasal cavity and paranasal sinus tumors, and 7-field non-coplanar IMRT plan and VMAT plans were generated with 6-MV photon beams specially selected for each patient anatomy. The effects on planning target volume (PTV) and organ-at-risk (OAR) were evaluated using AXB and AAA in each treatment technique to compare the accuracy of the calculation. RESULTS Conformity Index (CI) values for PTV were found to be 1.02 +/- 0.02 and 1.03 +/- 0.03 for VMAT(AAA) and VMAT(AXB) plans, respectively and 1.18 +/- 0.03 and 1.20 +/- 0.02 for IMRTAAA and IMRTAXB plans, respectively. Regarding heterogeneity index (HI) values, VMAT(AAA) and VMA(AXB) plans (0.025 +/- 0.02; 0.029 +/- 0.02) were found to have better HI values than IMRTAAA and IMRTAXB plans (0.246 +/- 0.02; 0.335 +/- 0.03). Depending on the technique and algorithm used, a dose difference of 4%-14% was detected between PTV Drain values. CONCLUSION The selection of AXB algorithm treatment regions with high tissue heterogeneity will give more accurate dose calculation results for PTV and healthy tissues.

Açıklama

Anahtar Kelimeler

Anisotropic analytical algorithm, Acuros XB, nasal cavity, radiotherapy for paranasal sinus, integral dose

Kaynak

TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY

WoS Q Değeri

Q4

Scopus Q Değeri

Cilt

Sayı

Künye