Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

dc.WoS.categoriesInstruments & Instrumentationen_US
dc.authorid0000-0002-9007-8260en_US
dc.contributor.authorYetkin, Elif Aslı
dc.date.accessioned2020-12-08T06:50:20Z
dc.date.available2020-12-08T06:50:20Z
dc.date.issued2020-06
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Enerji Sistemleri Mühendisliği Bölümüen_US
dc.description49 pagesen_US
dc.description.abstractMeasurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb(-1) . The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using Co-60 sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.en_US
dc.fullTextLevelFull Texten_US
dc.identifier.doi10.1088/1748-0221/15/06/P06009en_US
dc.identifier.issn1748-0221
dc.identifier.urihttps://hdl.handle.net/11411/2780
dc.identifier.urihttps://doi.org/10.1088/1748-0221/15/06/P06009
dc.identifier.wosWOS:000545350900009en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.issue6en_US
dc.language.isoenen_US
dc.nationalInternationalen_US
dc.numberofauthors1000+en_US
dc.publisherIOP Publishing Ltd.en_US
dc.relation.ispartofJournal of Instrumentationen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectLarge detector systems for particle and astroparticle physicsen_US
dc.subjectScintillators, scintillation and light emission processes (solid, gas and liquid scintillators)en_US
dc.titleMeasurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeteren_US
dc.typeArticleen_US
dc.volume15en_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
2020WosYetkin.pdf
Boyut:
1.39 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: