Performance of the CMS muon detector and muon reconstruction with proton-proton collisions at root s=13 TeV

Yükleniyor...
Küçük Resim

Tarih

2018-06

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

IOP PUBLISHING LTD

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy root s = 13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.

Açıklama

Anahtar Kelimeler

Muon spectrometers, Particle tracking detectors (Gaseous detectors)

Kaynak

JOURNAL OF INSTRUMENTATION

WoS Q Değeri

Q3

Scopus Q Değeri

Cilt

Sayı

Künye