Design and implementation of a low-cost high-performance syringe pump system
dc.authorscopusid | 58456930500 | |
dc.authorscopusid | 57207725553 | |
dc.authorscopusid | 22955271900 | |
dc.authorscopusid | 24470047300 | |
dc.contributor.author | Coskun, H. | |
dc.contributor.author | Gul, O. | |
dc.contributor.author | Ferhanoglu, O. | |
dc.contributor.author | Gokdel, Y.D. | |
dc.date.accessioned | 2024-07-18T20:17:03Z | |
dc.date.available | 2024-07-18T20:17:03Z | |
dc.date.issued | 2018 | |
dc.description | 21st National Biomedical Engineering Meeting, BIYOMUT 2017 -- 24 November 2017 through 26 November 2017 -- -- 140363 | en_US |
dc.description.abstract | This study describes design and implementation of a high- performance, low-cost, syringe pump device. Proposed device can be used with different injectors having volumes that are ranging from a common 0.5 mL to a larger 60 mL. This adaptable and programmable syringe pump provides high accuracy and adjustable flow rate in a simple mechanical manner and costs approximately $200. Developed system was tested on an optical table in lab conditions. It is measured that system can provide rates up to 0.05 mL/h, when used on a 0.5 mL syringe whereas the maximum volume 60 mL injector can provide a flow rate of 5.8 mL/h. Mean flow rate error of the system is calculated as 1.33%. Time-distance plots reveal a high degree of linearity and negligible hysteresis. Thus, the manufactured syringe pump is an excellent candidate as a high-precision liquid delivery system for low-resource settings. © 2017 IEEE. | en_US |
dc.identifier.doi | 10.1109/BIYOMUT.2017.8478979 | |
dc.identifier.isbn | 9781538653401 | |
dc.identifier.scopus | 2-s2.0-85056409672 | en_US |
dc.identifier.scopusquality | N/A | en_US |
dc.identifier.uri | https://doi.org/10.1109/BIYOMUT.2017.8478979 | |
dc.identifier.uri | https://hdl.handle.net/11411/6390 | |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | en_US |
dc.relation.ispartof | 2017 21st National Biomedical Engineering Meeting, BIYOMUT 2017 | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Biomedical Engineering | en_US |
dc.subject | Costs | en_US |
dc.subject | Syringes | en_US |
dc.subject | Design And İmplementations | en_US |
dc.subject | High-Precision | en_US |
dc.subject | Lab Conditions | en_US |
dc.subject | Liquid Delivery Systems | en_US |
dc.subject | Low-Resource Settings | en_US |
dc.subject | Optical Tables | en_US |
dc.subject | Programmable Syringe Pump | en_US |
dc.subject | Time Distance | en_US |
dc.subject | Jet Pumps | en_US |
dc.title | Design and implementation of a low-cost high-performance syringe pump system | en_US |