A Microwave Ring Resonator Based Glucose Sensor

dc.authoridCamli, Berk/0000-0002-9651-9389|Torun, Hamdi/0000-0002-7882-286X|Torun, Hilmi/0000-0001-6730-8809|Salman, Seyhan/0000-0002-6124-3706|Salman, Seyhan/0000-0002-6124-3706|Kusakci, Emre/0000-0001-7603-1186
dc.authorwosidCamli, Berk/GQY-8245-2022
dc.authorwosidTorun, Hamdi/H-6531-2014
dc.authorwosidTorun, Hilmi/JTT-8917-2023
dc.authorwosidSalman, Seyhan/F-3154-2015
dc.authorwosidSalman, Seyhan/I-1175-2012
dc.contributor.authorCamli, Berk
dc.contributor.authorKusakci, Emre
dc.contributor.authorLafci, Berkan
dc.contributor.authorSalman, Seyhan
dc.contributor.authorTorun, Hamdi
dc.contributor.authorYalcinkaya, Arda
dc.date.accessioned2024-07-18T20:56:04Z
dc.date.available2024-07-18T20:56:04Z
dc.date.issued2016
dc.departmentİstanbul Bilgi Üniversitesien_US
dc.description30th Eurosensors Conference -- SEP 04-07, 2016 -- Budapest, HUNGARYen_US
dc.description.abstractA microwave ring resonator based glucose detecting biosensor incorporating glucose oxidase enzyme is presented. Sensor uses a split ring resonator as a transducer, where the sensing operation is done by the observation of shifts in its resonant frequency. Resonator was fabricated with basic fabrication techniques and the enzyme was immobilized via conductive polymer agent PEDOT: PSS. Experimentally observed redshift of resonant frequency of the sensor in response to different loading conditions are in agreement with simulation results and theoretical expectations. Sensor selectivity is confirmed with control experiments conducted with NaCl solutions. Experiments done with different glucose solution concentrations yielded a sensor sensitivity of 0.174MHz/mgml(-1). (C) 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.en_US
dc.identifier.doi10.1016/j.proeng.2016.11.127
dc.identifier.endpage468en_US
dc.identifier.issn1877-7058
dc.identifier.scopus2-s2.0-85009959300en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage465en_US
dc.identifier.urihttps://doi.org/10.1016/j.proeng.2016.11.127
dc.identifier.urihttps://hdl.handle.net/11411/8843
dc.identifier.volume168en_US
dc.identifier.wosWOS:000391641300111en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherElsevier Science Bven_US
dc.relation.ispartofProceedings of The 30th Anniversary Eurosensors Conference - Eurosensors 2016en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMetamaterialsen_US
dc.subjectSplit Ring Resonatorsen_US
dc.subjectBiosensorsen_US
dc.subjectGlucoseen_US
dc.subjectGoxen_US
dc.subjectBiosensorsen_US
dc.titleA Microwave Ring Resonator Based Glucose Sensoren_US
dc.typeConference Objecten_US

Dosyalar